Floater Weighting
Secure the floater counterweight 10 cm from its end by tying the floater wire to the counterweight at both ends to prevent movement. Position the counterweight either 20 cm below the water supply inlet or 25 cm below the tank’s surface, whichever is less, or according to customer preference. Tie a knot in the wire at the appropriate location to secure the setting, considering the wire’s exit point on the tank.
For a small floater (specifically designed for Tamam), position the floater level 5 cm above the water supply inlet.
Floater Installation
To install the additional floater in the ground tank, select a suitable location free of obstructions that could impede its movement or operation. Secure the floater by pulling the floater wire through an opening at the top of the tank, tying a knot on the inside, and then tying a second knot on the outside to ensure stability.
Installation of the small floater (specifically designed for Tamam) is performed according to customer preference, ensuring secure attachment.
Floater Connection
Connect the common floater wire to wire No. 7 on the Tamam device. Connect the empty floater wire to wire No. 8 and the full floater wire to wire No. 9. Ensure all wire connections are located outside the tank to prevent exposure to water and moisture.
If an additional wire is required between the Tamam device and the float, use a three-wire cable that is weather and heat resistant.